INDUSTRY / ENERGY STORAGE (ESS) / 48V TELECOM TOWERS & DATA CENTER UPS

Lithium Battery Packs & Cells for Telecom Base Stations & UPS Backup Power

5G/4G macro telecom base stations, 19-inch / 23-inch rack-mount data center UPS cabinets, and railway signaling backup rooms run on -48V DC rectifiers (15S 48.0V or 16S 51.2V LiFePO4). AntBattery supplies 3.2V 50Ah, 100Ah, 105Ah, and 150Ah prismatic LiFePO4 cells and custom 3U/4U/5U rack modules.

Application Scope
5G/4G telecom base stations, 19-inch rack UPS, railway signaling backup
Voltage Platform
48 V (15S) and 51.2 V (16S) 50Ah / 100Ah / 150Ah 3U/4U rack packs
Cell Options
3.2V 50Ah, 100Ah, 105Ah & 150Ah Prismatic LiFePO4 Cells
3.2V 50Ah LiFePO4 prismatic battery cell
48V TELECOM TOWERS & DATA CENTER UPS 3.2V 50Ah LiFePO4 Prismatic Battery Cell

MATCHED BATTERY PACKS & CELLS · 48V TELECOM TOWERS & DATA CENTER UPS

Battery Packs and Grade-A Cells for Telecom Base Stations & UPS Backup Power

← Back to Energy Storage (ESS)

CUSTOM BATTERY PACK ENGINEERING (48V TELECOM TOWERS & DATA CENTER UPS)

Need a Custom 48 V (15S) and 51.2 V (16S) 50Ah / 100Ah / 150Ah 3U/4U rack packs Pack for Telecom Base Stations & UPS Backup Power?

AntBattery currently supplies matched bare cells (3.2V 50Ah, 100Ah, 105Ah & 150Ah Prismatic LiFePO4 Cells) and assembles custom 48 V (15S) and 51.2 V (16S) 50Ah / 100Ah / 150Ah 3U/4U rack packs series-parallel battery packs for 5G/4G telecom base stations, 19-inch rack UPS, railway signaling backup with tailored L × W × H enclosures, BMS current ratings, and wire harnesses.

Configure Custom Battery Pack

ENGINEERING VERIFICATION

Telecom Base Stations & UPS Backup Power Operating Conditions and Cell / Pack Sizing

Submit Compartment & Load Specs

Parent & sibling categories in Energy Storage (ESS): Solar Street Lights & Outdoor Lighting, Residential Solar Storage & 48V Server Rack, Commercial & Industrial (C&I) BESS, Portable Power (Power Stations & Mobile Energy Kits). Related voltage catalog: 48V Telecom & UPS Prismatic Platforms.

01

15S (48.0V Nominal) vs 16S (51.2V Nominal) Telecom Rectifier Float Match

Legacy -48V telecom rectifiers set to 53.5V–54.0V float voltage pair directly with 15S LiFePO4 (54.0V–54.75V full charge), whereas programmable modern rectifiers and solar-hybrid base stations use 16S (51.2V).

02

19-Inch 3U (50Ah/100Ah) & 4U/5U (150Ah) Server Cabinet Depth Limits

Outdoor telecom street cabinets restrict battery drawer depth to 400 mm–500 mm; 3.2V 50Ah, 100Ah, 105Ah, and 150Ah prismatic cells fit standard 19-inch rack chassis.

03

Active Current-Limiting Function when Paralleling New & Old Rack Modules

Telecom towers often mix battery strings or parallel 4 to 10 rack modules; integrated DC-DC current-limiting BMS circuits prevent high inrush currents when a discharged pack reconnects to the live 48V bus.

04

SNMP / RS485 / Dry-Contact Alarm Integration with Base Station RTUs

Custom telecom rack packs provide RS485/CAN telemetry and dry-contact alarm relays for remote tower monitoring.

TECHNICAL REFERENCE

Telecom Base Stations & UPS Backup Power Battery Engineering FAQs

Why do many -48V telecom base stations specify 15S LiFePO4 instead of 16S?

Existing -48V lead-acid telecom rectifiers operate at a 53.5V float voltage, which is too low to fully charge and balance a 16S LiFePO4 pack (requiring 56.0V–57.6V) but matches a 15S LiFePO4 pack (48.0V nominal, 54.0V full charge) without replacing the rectifier.

What prismatic cell capacities are used in 48V 50Ah, 100Ah, and 150Ah telecom rack batteries?

A 48V 50Ah 3U rack pack uses fifteen or sixteen 3.2V 50Ah prismatic cells; a 48V 100Ah/105Ah 3U/4U pack uses 3.2V 100Ah or 105Ah cells; and a 48V 150Ah pack uses 3.2V 150Ah prismatic cells.

How do LiFePO4 telecom packs perform in unairconditioned outdoor desert street cabinets?

Prismatic LiFePO4 cells tolerate 45°C–55°C ambient cabinet temperatures with far lower calendar aging than VRLA/AGM lead-acid batteries, which rapidly dry out above 35°C.

Can we buy bare 3.2V 50Ah, 100Ah, 105Ah, and 150Ah prismatic cells for telecom pack assembly?

Yes. We supply Grade-A batch-sorted 50Ah, 100Ah, 105Ah, and 150Ah prismatic LiFePO4 cells as well as custom 19-inch rack modules.

CUSTOM ENGINEERING & QUOTATION

Telecom Base Stations & UPS Backup Power Battery Engineering Inquiry

Share your telecom rectifier float voltage (15S 48V or 16S 51.2V), rack height/depth (3U/4U/5U), capacity (50Ah/100Ah/150Ah), and order volume.

Discuss on WhatsApp

Send Your Project Requirements

Fields marked * are required. Direct engineering response within 24 hours.